Electrical service and panel inspection checklist

Use this checklist for a new service, a panel change or a subpanel. It covers the service (size, meter base, working clearance, grounding electrode and bonding) and the panel (directory, breaker sizes, neutrals and grounds, torque, openings and labels), with a space to record grounding electrode resistance.

Use it free on your phone
Free checklist from SRENE.io · myBivy for Trades

Service & panel

New service, panel change or subpanel.

JobArea / floorDateChecked by
ServicePASSFAILN/A
Service size matches plans
Meter base / CT cabinet installed and sealed
Service clearances (working space)
Grounding electrode resistance ohms
Bonding: water, gas, structural steel
PanelPASSFAILN/A
Panel directory complete and accurate
Breaker sizes match conductors
Neutrals and grounds separated (subpanels)
Torque to spec
Knockouts / openings closed
Arc-flash / warning labels
Notes
Electrician (QC)NameSignatureDate
GCNameSignatureDate
Electrical inspectorNameSignatureDate

Run this checklist free on your phone, with photos and signatures: myBivy for Trades at srene.io. A field checklist, not the code; follow the code and amendments your jurisdiction has adopted.

What gets missed most

  • A panel directory that's blank or vague.
  • Neutrals and grounds tied together in a subpanel.
  • Open knockouts or missing filler plates.
  • Not enough working space in front of the panel.

This is a field checklist, not the code. Your inspector enforces the code and local amendments your jurisdiction has adopted.

Questions trades ask

What does an inspector check on a panel change?

Service size against the plans, grounding and bonding, working clearance, breaker sizes against conductor sizes, the panel directory, and that the panel is closed up and labeled. Requirements vary, so confirm with your inspector.

Why are neutrals and grounds separated in a subpanel?

Neutral and ground are bonded together at one point, the service. Panels downstream keep them on separate bars. Check your adopted code for the specifics.

Do I need to record grounding electrode resistance?

Some jurisdictions and specs ask for it. The checklist has a space for the reading in ohms so it's on record if you need it.

Can I use this checklist on my phone?

Yes. It's built into myBivy for Trades, free for up to 5 people: Pass, Fail or N/A on each item, notes, photos and readings, signatures on site, and a clean PDF for the GC.

Free for trade contractors

Pass the first inspection.

This checklist is built into myBivy for Trades: Pass, Fail or N/A on every item, notes, photos and readings, the GC signs on site, and a clean PDF goes out the same day. Free for up to 5 people.

The inspection checklist app · All free trade checklists · Free field forms